Lugar de origen: | Henan |
Nombre de la marca: | Sanwu |
Certificación: | ISO CCC |
Número de modelo: | YJLV |
Cantidad de orden mínima: | el 1000M |
---|---|
Precio: | Negotiable |
Detalles de empaquetado: | Tambor de acero o de madera de la exportación |
Tiempo de entrega: | 1-15days |
Condiciones de pago: | L/C, T/T, Western Union |
Capacidad de la fuente: | 200 toneladas por día |
material: | Cu/Al+xlpe/pe/pvc | Voltaje: | Debajo de 35kv |
---|---|---|---|
Estándar: | IEC, ASTM, BS, ESTRUENDO, NFC, CSA | ||
Alta luz: | Cable de transmisión de YJV22 LV,Cable de transmisión de YJV LV,Cable aislado del PVC YJV22 |
Low Voltage XLPE PVC Insulated Armoured Flexible Electric (YJV/YJV22-0.6/1KV) Power Cable
Application:
This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.
Technical Parameter:
When the cable is running normally, the Maximum temperature of conductor is 90℃; and is 250 ℃ when the short circuit (Max. last 5s) happens.
The ambient temperature of installation shall not lower than 0 degrees.
Minimum bending radius is 12 D (“D” refers to cable diameter)
Jacketed Aluminum Duplex Conductor Underground Power Cable Features and Benefits:
Jacketed Aluminum Duplex Conductor Underground Power Cable Applications:
Jacketed Aluminum Duplex Conductor Underground Power Cable Options:
Single Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
1*1.5 | 0.7 | 1.5 | 6 | 53 | 53 | ≤12.1 | ≤12.1 | 3.5 | 26 | 26 | 33 | 32 |
1*2.5 | 0.7 | 1.5 | 6 | 68 | ≤7.41 | 3.5 | 34 | 43 | ||||
1*4 | 0.7 | 1.5 | 7 | 87 | 64 | ≤4.61 | ≤7.41 | 3.5 | 44 | 35 | 56 | 42 |
1*6 | 0.7 | 1.5 | 7 | 110 | 73 | ≤3.08 | ≤4.61 | 3.5 | 56 | 45 | 70 | 54 |
Two Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
2*2.5 | 0.7 | 1.8 | 11.8 | 151 | 118 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
2*4 | 0.7 | 1.8 | 12.7 | 198 | 146 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
2*6 | 0.7 | 1.8 | 13.7 | 250 | 173 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
2*10 | 0.7 | 1.8 | 16.3 | 374 | 245 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×1.5 | 0.7 | 1.5 | 10 | 145 | - | ≤12.1 | - | 3.5 | 20 | - | 27 | - |
3×1.6 | 0.7 | 1.5 | 11 | 185 | 140 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
3×4 | 0.7 | 1.5 | 12 | 250 | 175 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6 | 0.7 | 1.5 | 13 | 320 | 210 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10 | 0.7 | 1.5 | 15 | 450 | 260 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
4×4 | 0.7 | 1.5 | 13 | 253 | 155 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
4×6 | 0.7 | 1.5 | 14 | 337 | 184 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
4×10 | 0.7 | 1.5 | 16 | 501 | 258 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Persona de Contacto: Emily Wang
Teléfono: +8615139958913
El PVC XLPE PE aisló al conductor de aluminio Cable de B-232 B-500
Cable de aluminio negro impermeable de alto voltaje de ABC XLPE
BS subterráneos 215 95m m desnudos AAC Ant Conductor
ASTM BS Todo conductor de aluminio para líneas aéreas de transmisión
Conductor ligero combinado del estruendo AACSR de ASTM
La plata cubrió el alambre de aluminio de arriba de acero de la base AACSR 0.6/1kv
El acero reforzó el conductor de la aleación de aluminio 216mm2 AACSR